LL Gel ISE Reference Electrode
Our most advanced and popular reference electrode for measurement and titration. Green gel inner reference solution gives unsupassed signal stability and rapid stabilization times. Double junction Ag/AgCl reference electrode with contamination resistent fixed ground glass diaphragm and stable constant electrolyte flow. |
6.0750.100 |
Ag/AgCl Reference Electrode, RF Shielded, Long Length
RF Shielded Ag/AgCl LL (Long Life) glass reference electrode for diferential potentiometry. Long length for sample changers. |
6.0729.110 |
Ag/AgCl Reference Electrode, RF Shielded, LiCl
RF Shielded Ag/AgCl LL (Long Life) glass reference electrode for diferential potentiometry. Prefilled with LiCl in ethanol. |
6.0729.108 |
Ag/AgCl Reference Electrode, RF Shielded
RF Shielded Ag/AgCl LL (Long Life) glass reference electrode for diferential potentiometry. |
6.0729.100 |
Ag/AgCl Reference Electrode, Glass Diaphragm, Long Length
Ag/AgCl LL (Long Life) glass reference electrode for diferential potentiometry. Long length for sample changers. |
6.0726.110 |
Ag/AgCl Reference Electrode, Glass Diaphragm , LiCl
Ag/AgCl LL (Long Life) glass reference electrode for diferential potentiometry. Prefilled with LiCl in ethanol. |
6.0726.108 |
Ag/AgCl Reference Electrode, Glass Diaphragm, KCl
Ag/AgCl LL (Long Life) glass reference electrode for diferential potentiometry. Prefilled with KCl electrolyte. |
6.0726.107 |
Ag/AgCl Reference Electrode, Glass Diaphragm
Ag/AgCl LL (Long Life) glass reference electrode for diferential potentiometry. |
6.0726.100 |
Conductivity Measuring Cell, c = 0.1 cm-1 with PT1000 (Plug N)
Stainless steel bodied conductivity measuring cell, c = 0.1 cm-1, with PT1000 Temperature Sensor and Plug N for 856 Conductivity Module. For conductivity of injectible water by USP <645> and samples with conductivity of < 300 µS/cm. |
6.0916.040 |
5-Ring Conductivity Measuring Cell, c = 1.0 cm-1 with integrated PT1000 (Plug N)
Intelligent conductivity measuring cell with PT1000 temperature sensor for 856 conductivity module. Exclusive Metrohm 5-ring measuring technology to eliminate signal noise and drift. c = 1.0 cm-1. |
6.0915.130 |
5-Ring Conductivity Measuring Cell, c = 0.7 cm-1 with integrated PT1000 (Plug N)
Intelligent conductivity measuring cell with PT1000 temperature sensor for 856 conductivity module. Exclusive Metrohm 5-ring measuring technology to eliminate signal noise and drift. c = 0.7 cm-1. |
6.0915.100 |
Conductivity Measuring Cell, c = 0.1 cm-1 with PT1000 (4 x B plug)
Stainless steel bodied conductivity measuring cell, c = 0.1 cm-1, with PT1000 Temperature Sensor with 4 x B connectors. For conductivity of injectible water by USP <645> and samples with conductivity of < 300 µS/cm. |
6.0914.040 |
Conductivity Measuring Cell, c = 0.8 cm-1 with PT1000 (4 x B)
Conductivity cell with plastic shaft and PT1000 temperature sensor. c = 0.8 cm-1 with 4 x B connectors. |
6.0912.110 |
Conductivity Measuring Cell, c = 0.8 cm-1 for Sample Changers
Conductivity cell with glass shaft. c = 0.8 cm-1 with Metrohm G plug in head and extended length for sample changers. Requires connection cable 6.2104.080 or 6.2104.110. |
6.0910.120 |
Conductivity Measuring Cell c = 0.8 cm-1 with PT100 and 4 x B connectors
Conductivity cell with glass shaft. c = 0.8 cm-1 with PT100 and 4 x B connectors |
6.0908.110 |
Conductivity Measuring Cell c = 10 cm-1 with 2 x B connectors
Immersion conductivity cell. c = 10 cm-1 with glass shaft and 2 x B connectors |
6.0901.260 |
Conductivity Measuring Cell c = 0.1 cm-1 with 2 x B connectors
Immersion conductivity cell. c = 0.1 cm-1 with glass shaft and 2 x B connectors |
6.0901.040 |
PT1000 Temperature Sensor Stainless Steel Probe
Speciality stainless steel bodied PT1000 temperature sensor for use with Spearhead pH electrode. For temperature measurement in semisolid and liquid matrices. Integrated cable with 2mm B plugs for Titrando, 780, 781, 826 and 827. |
6.1114.010 |
PT1000 Temperature Sensor, Long for Sample Changers
Standard glass bodied PT1000 with long length for use with sample changers. Requires connection cable 6.2104.140 or 6.2104.150. |
6.1110.110 |
PT1000 Temperature Sensor
Standard glass bodied PT1000. Requires connection cable 6.2104.140 or 6.2104.150. |
6.1110.100 |
| Cables and Adapter Plugs |
Connection Cable: Plug G to 2 x 2 mm plug - 1 m
Connection cable for separate PT1000 temperature sensors. |
6.2104.140 |
Connection Cable: Plug G to 2 x 2 mm plug - 2 m
Connection cable for separate PT1000 temperature sensors. |
6.2104.150 |
Connection Cable: Plug G to 2 x 4 mm B plug - 1 m
Connection cable for 6.0910.120 conductivity cell, 1 m length |
6.2104.080 |
Connection Cable: Plug G to 2 x 4 mm B plug - 2 m
Connection cable for 6.0910.120 conductivity cell, 2 m length |
6.2104.110 |
Adapter: 4 mm Plug to 2 mm Socket (red color)
Adapter plug to connect new 2mm temperature cables to 7xx Titrino and prior instruments with 4mm B (bannana) connections. |
6.2103.150 |
Adapter: 2 mm Plug to 4 mm Socket (black color)
Adapter plug to connect 4mm B (bananna) temperature cables to 2mm Titrando class instruments. Black colored plug. |
6.2103.140 |
Adapter: 2 mm plug to 4 mm socket (red color)
Adapter plug to connect 4mm B (bananna) temperature cables to 2mm Titrando class instruments. Red colored plug. |
6.2103.130 |
Adapter: 4 x socket B to Plug N for 856 Conductivity Module
Adapter box for the connection of standard Metrohm conductivity measuring cells with 4 mm B plugs to the 856 conductivty module. |
6.2103.160 |